Home / Sprinklers / Without a blowout

Sprinklers & irrigation

How do I winterize my sprinkler system without a blowout?

Direct answer

You can winterize without a compressor only if the system was installed to drain — manual drain valves at the ends and low points of the piping, or automatic drains that open when pressure drops. Shut off the irrigation water, relieve pressure, drain the backflow preventer and other exposed parts, open the drains, and insulate anything above ground. If you cannot confirm that layout, or you live where frost reaches the buried pipes, manufacturers and Colorado State University Extension treat a compressed-air blowout as the more reliable method.

What you’ll need

  • Eye protection
  • The irrigation shutoff (often a ball valve, gate valve, or stop-and-waste in a basement, crawl space, or valve box)
  • Access to every manual drain valve, plus the backflow preventer’s test cocks and isolation valves
  • A key or wrench if your stop-and-waste valve is buried (Colorado State University Extension notes some are several feet down; do not force the valve)
  • Pipe insulation or an insulated cover for exposed backflow preventers and piping

Steps

  1. Confirm the system was designed to drain. Hunter Industries says to use the manual-drain method only if you can confirm that manual valves are at the end and low points of the irrigation piping. Attempting this on a system that was not installed that way “may lead to negative results and/or damage from residual water.” If you do not know your system type, Hunter says it is best to use the blowout method (or hire a professional).
  2. Shut off the irrigation water supply at the isolation valve near the meter, basement, or backflow assembly. Oklahoma State University Extension and Texas A&M’s School of Irrigation both start with turning the water off.
  3. Put the controller in the Off position. Hunter recommends leaving the controller powered and turning the dial or switch to Off so it cannot activate solenoids. For outdoor dial controllers, Hunter notes that heat from the transformer can help keep condensation from forming in the enclosure.
  4. Relieve pressure before opening drains. Rain Bird’s manual-drain procedure: after the mainline shutoff is closed, open one control valve (by hand or from the timer) to relieve pressure on the mainline, then slowly open the manual drain valve. Wear eye protection. Repeat for every manual drain on the mainline.
  5. If you have automatic drain valves, Rain Bird describes them as spring-loaded devices on heads or pipes that remove water every time the system is shut off, so you typically do not open them by hand. After you shut off the water and relieve pressure, check for heavy puddling on the soil, which can mean a drain is stuck open. Hunter’s related PDF guidance describes automatic drains that open when pressure in the piping falls below 10 psi.
  6. Drain the pipe between the house shutoff and the backflow preventer. Hunter’s manual-drain steps include opening the boiler-drain valve or the drain cap on a stop-and-waste valve, then opening the test cocks on the backflow device.
  7. Leave backflow isolation ball valves partly open for the winter. Hunter and Colorado State University Extension both recommend leaving those valves at about a 45-degree angle (roughly half open) after you have exercised them, because a ball valve that is fully open or fully closed can trap water in the valve body, where it can freeze and cause damage. Leave the test cocks open as those instructions describe, and remember to close test cocks before you repressurize in spring.
  8. Drain sprinkler bodies that have check valves. Hunter says that if your sprinklers have check valves, you need to pull up on the sprinklers so water can drain out the bottom of the body. Even with drains open, some water can remain in the backflow, piping, and heads, depending on where the drains sit.
  9. Insulate exposed parts. Oklahoma State University Extension and Texas A&M both tell homeowners to insulate above-ground PVC, the main shutoff, and backflow preventers after they are drained.
  10. Close manual drain valves after the lines have emptied, following Hunter’s winterizing instructions, so they are not left open. Do not turn the water back on until you are ready in the spring and have closed test cocks and returned isolation valves to the positions your manual specifies.

Common mistakes and variations

This is not a universal substitute for a blowout

Colorado State University Extension (fact sheet reviewed August 2025) says draining with manual or automatic valves “is not recommended” as the only method, because subsurface pipes tend to shift over time and you cannot visually inspect the lines. In that publication, “the only positive way to be sure enough water has been expelled” is a compressed-air blowout. The same fact sheet states that systems with electric valves must be blown out with air because there is otherwise no way to drain water off the top of the valve diaphragm.

Mild-winter vs hard-freeze climates

Texas A&M’s School of Irrigation says that for most of Texas, turning the controller and water supply off, insulating exposed PVC, and draining above-ground components (including backflow assemblies) can protect a system from light to mild freezes. It also notes that the blowout method is most commonly used in the northern United States, where the ground can freeze down to the buried pipelines, and that most landscape systems in Texas are not designed for a blowout.

No drain valves

Oklahoma State University Extension suggests having drain valves retrofitted if the system does not have them, or hiring a professional to blow the system out with compressed air. That extension article tells homeowners not to attempt a blowout themselves because improper pressure can damage the system. See our blowout guide for manufacturer pressure limits if you or a contractor use compressed air.

Drip tape and soaker hoses

Oklahoma State University Extension says to drain drip tape or soaker hoses and store them out of sunlight. If a hose is left outside and freezes, leave it in place until it thaws; moving it while frozen can damage it.

FAQ

Can I skip a blowout if I have automatic drain valves?

Only if the system was actually installed with automatic or manual drains at the low points and the piping still slopes toward them. Hunter Industries says to use this method only if you can confirm those valves. Colorado State University Extension does not recommend relying on gravity drains alone in cold climates, because buried pipe can shift and trap water you cannot see.

Do I close manual drain valves after they drain, or leave them open until spring?

Hunter’s winterizing instructions say to close all manual drain valves after the water has drained, and not to leave them open after a blowout. Oklahoma State University Extension tells homeowners to close the valves next spring before turning the system back on. Follow your installer or manufacturer if they specify one approach, and do not pressurize the system in spring while a drain is still open.

What about the irrigation controller?

Hunter recommends leaving power on and turning the dial or switch to Off, so the controller does not activate solenoids and, for outdoor units, the transformer can help limit condensation. Texas A&M’s School of Irrigation lists turning the controller off as part of a basic winterization for light freezes.

Is this enough in a hard-freeze climate?

Not necessarily. Texas A&M notes that compressed-air blowouts are most commonly used in the northern United States, where frost can reach the buried pipelines. Colorado State University Extension states that the only positive way to be sure enough water has been expelled is a blowout with compressed air.

Sources

We checked these pages and documents while writing this guide. Follow your own manual if it differs.

  1. Winterizing Your Irrigation System — Hunter IndustriesOfficial Hunter winterization page: manual-drain vs blowout, when not to use gravity drains, backflow valve position, check-valve heads, and controller Off-but-powered guidance.
  2. Fall is Blow-Out Season — Rain BirdRain Bird homeowner guidance dated October 20, 2025: eye protection, relieving pressure before opening manual drains, and how automatic drain valves behave.
  3. Home Sprinkler Systems: Preparing Your Sprinkler System for Winter — Colorado State University ExtensionCSU Extension fact sheet (published 2014, reviewed August 2025). Explains why gravity draining is unreliable and when electric valves need a blowout.
  4. Tips for Winterizing a Home Landscape Irrigation System — Oklahoma State University ExtensionNovember 27, 2022 Grow column: shut off water and timer, drain and insulate exposed parts and backflow devices, open manual valves, and hire a professional for a blowout.
  5. Winterization — Texas A&M School of IrrigationBasic winterization for light to mild freezes in most of Texas, and a note that blowouts are more common where frost reaches buried pipe.

Related guides