Home / RV & camper / Tankless water heater
RV & camper
How do I winterize a camper or RV with a tankless water heater?
Do not copy a tank-heater bypass routine onto a tankless unit unless your manual says to. Lippert’s Girard GSWH-2 official manual says the heat exchanger holds very little water, does not require a bypass kit, and should be winterized with the rest of the system — either by blowing out residual water or by running non-toxic antifreeze until it flows from every tap. Furrion’s tankless service manual allows antifreeze in the heater (plan about 1 extra liter) and says that if you do use a bypass, you must first evacuate the heater with compressed air. Always add the heater maker’s steps on top of your coach manufacturer’s winterizing procedure.
What you’ll need
- The owner’s manuals for both the RV and the water heater (Girard/Lippert, Furrion, Truma, or another brand — they are not identical)
- Non-toxic RV water-system antifreeze if you use the wet method, plus about 1 extra liter if you are filling a Furrion-type heater
- Or a regulated air compressor and blow-out plug if you use the compressed-air method
- The winterizing valve or suction hose at the water pump, if your coach has one
Steps
- Identify the exact heater model and read both manuals. The notes below are from official Girard GSWH-2 and Furrion 2.4 gpm (FWH09A series) documents. Other brands and generations can differ. If the coach manual and the heater manual disagree, do not guess — use the stricter or model-specific instruction, or ask the dealer.
- Decide whether you are storing the rig or using it in the cold. For storage, you must winterize the plumbing. Girard’s GSWH-2 also has a built-in “antifreeze device” or winter-use thermostat for operation in freezing weather: it can start the burner below 38°F and stop above 58°F, but only if the ON/OFF switch is left ON, 12-volt power is present, and the LP tank has fuel. The manual states clearly that this will not protect the rest of the RV’s plumbing. That is not the same as pumping antifreeze for storage.
- Skip a tank-style bypass unless your heater manual allows it. Girard: the small volume in the heat exchanger “DOES NOT require the installation of a bypass kit.” Lippert’s Girard service manual goes further and says winterization bypass kits are not recommended on a tankless system because they can cause plumbing issues. Furrion: you may use an optional bypass, but “the water heater MUST be evacuated with compressed air” first.
- Drain the coach as the RV manufacturer describes (fresh tank, low-point drains, and any heater drain or filter your unit has). For storage, Furrion’s service manual also has you turn off the gas supply and the water heater’s main switch, then drain the heater by removing the filter cover and drain plug.
- Choose compressed air or antifreeze, then include the heater in the path.
- Compressed air (Girard): drain water from the system, opening one tap at a time, and use compressed air to purge what remains.
- Compressed air (Furrion): do not exceed 50 psi in the water heater. During the coach blowout, isolate the heater by closing other drains and faucets and opening only the water heater drain plug, so air actually evacuates the unit.
- Antifreeze (both): follow the RV manufacturer’s method and fill the system with non-toxic antifreeze until it flows from each tap. Furrion adds that antifreeze can be used directly in the water heater and to plan for an additional 1 liter to fill the system. Leave any required valves in the normal (not bypass) position unless you have already blown the heater out and your manual allows bypass.
- Finish the rest of the coach — cold lines, toilet, outdoor shower, drains, and filter canisters — using your RV manual. Then do not operate the water heater until you have flushed it.
- Before the next season, Furrion says to thoroughly flush the water heater and system with clean drinking water on both the hot and cold sides, drain it several times, and sanitize the water system as the coach manufacturer recommends.
Common mistakes and variations
Using a tank-heater checklist
On a tank heater, bypassing avoids filling a 6- or 10-gallon tank with antifreeze. On a Girard-style tankless unit, bypassing can leave the heat exchanger unprotected or create the plumbing issues Lippert warns about. Treat tankless as part of the circulating system unless your manual says otherwise.
Assuming gravity will empty the heat exchanger
If you intend to bypass a Furrion heater, the service manual requires a compressed-air evacuation first. Do not assume the unit is dry because a drain plug was opened.
Conflicting air-pressure numbers
Furrion’s service manual caps blowout pressure in the water heater at 50 psi. Some coach manuals use a lower city-inlet setting (the 2019 Winnebago Travato procedure regulates blow-out air to 30 psi or less). Use the lower of the limits that apply to your equipment.
FAQ
Should I bypass a tankless RV water heater?
Not by default. The official Girard GSWH-2 owner’s manual (Lippert) says the small amount of water in the heat exchanger does not require a bypass kit, and Lippert’s service manual says winterization bypass kits are not recommended because they can cause plumbing problems. Furrion’s service manual allows an optional bypass only after the heater has been evacuated with compressed air. Follow the manual for your exact model.
How much extra antifreeze does the tankless unit take?
Furrion’s 2.4 gpm tankless service manual says antifreeze can be used directly in the water heater and to plan for an additional 1 liter (about 1 quart) to fill the system. That is in addition to the antifreeze you already need for the rest of the coach.
What air pressure is safe if I blow it out instead?
Furrion’s service manual says not to exceed 50 psi in the water heater when blowing out the system, and to isolate the heater drain so air actually moves through the unit. Some complete coach procedures (for example the 2019 Winnebago Travato manual’s plumbing blow-out) regulate air at the city-fill inlet to 30 psi or less. Use the lower limit required by your heater and coach manuals.
Can I leave the tankless heater on in freezing weather instead of winterizing?
Only as a winter-use feature while the RV is being used, and only if your model has that device and you meet its conditions. Girard’s GSWH-2 manual describes a thermostat that can start the burner when the heat exchanger falls below 38°F and shut it off above 58°F, but only if the unit is left powered ON, 12-volt power is available, and there is enough LP gas. That feature does not protect the rest of the RV’s plumbing and is not a substitute for storage winterization.
Sources
We checked these pages and documents while writing this guide. Follow your own manual if it differs.
- Girard GSWH-2 Tankless Water Heater Owner’s Manual — Lippert (CCD-0006120)Official winterization section: no bypass kit required; compressed-air or non-toxic antifreeze methods; winter-use thermostat at 38°F / 58°F and its power and LP requirements.
- Girard GSWH-2 Troubleshooting and Service Manual — Lippert (CCD-0009390)States that winterization bypass kits are not recommended on this tankless system, and that freeze damage to the heat exchanger is not covered by warranty. Prefers RV antifreeze in the exchanger for best results.
- Furrion 2.4 gpm Tank-less Gas Water Heater Troubleshooting and Service Manual (CCD-0009617)Do not exceed 50 psi in the heater during blowout; isolate the heater drain; antifreeze may go through the heater (plan 1 L extra); optional bypass only after compressed-air evacuation; flush and sanitize next season.
- 2019 Winnebago Travato Operator’s Manual (via ManualsLib)Example of a coach-level blow-out limit (30 psi or less at the city-fill inlet). Cited for pressure context; your coach may differ.