Home / Small engines & generators / Portable generator
Small engines & generators
How do I winterize a portable generator?
For a gas portable generator, winterizing comes down to handling the fuel, changing the oil when your manual calls for it, protecting the cylinder if your manual says to, keeping an electric-start battery charged, and storing the generator cool, dry, level, and away from flames and sparks. The fuel step is where manufacturers differ most, and it usually depends on how long the generator will sit. Generac's GP Series manual says you can add stabilizer and run the engine 10 to 15 minutes, or drain the fuel and run it until it stops. Honda's EU2200i manual says to add stabilizer to a full tank and drain the carburetor for 2 months to a year, and to drain the tank and carburetor for a year or more. Champion's and Westinghouse's manuals also say to drain everything for longer storage (over 1 year for Champion, over 6 months for Westinghouse). Follow your own owner's manual. If you need the generator ready during winter outages, Generac recommends starting and running it for 30 minutes every 30 days. Only ever run it outdoors, well away from the house.
This guide is for general information only. It is not professional advice. Follow your owner's manual and local rules. If a step is beyond your skill, or involves gas, fuel, high-voltage wiring, or a pressurized blowout you cannot regulate safely, hire a licensed technician. Use at your own risk. Full disclaimer.
What you’ll need
- Your generator's owner's or operator's manual (Honda, Generac, Champion, and Westinghouse post manuals online)
- Fresh gasoline and a fuel stabilizer, used as the stabilizer's label directs, and/or an approved gasoline container and a hand pump if your manual says to drain the fuel
- A small container or funnel for draining the carburetor, if your manual has a carburetor drain
- Fresh engine oil of the type and amount your manual lists, a drain pan, and a sealed, leak-proof container for the used oil
- A spark plug wrench (and a replacement plug if your schedule calls for one), plus clean engine oil or fogging spray for the cylinder if your manual calls for it
- Safety glasses and gloves, a damp cloth, and a soft brush
- Electric-start models: a battery maintainer or the charger your manual specifies
- Dual-fuel models: the protective caps for the propane inlet and cylinder outlet
- A cover that won't trap moisture (Honda says not to use a plastic sheet)
This guide is independent. We are not affiliated with Honda, Generac, Champion, Westinghouse, Briggs & Stratton, or any other brand we cite. We cite their published instructions because they know their own equipment. The manuals we checked cover specific models (listed under Sources), and storage times, oil amounts, and maintenance intervals differ between brands and models. Treat these steps as an overview and follow your own manual where it differs.
Steps for a gasoline portable generator
- Decide how long it will sit, and read your manual's storage table. Gasoline can start to break down in about 30 days: Honda says fuel can deteriorate in as little as 30 days, Westinghouse says gasoline stored for as little as 30 days can deteriorate, and Generac says fuel stored over 30 days can go bad and damage fuel system parts. Honda says stale gasoline causes hard starting and leaves gum that clogs the fuel system, and that its warranty doesn't cover fuel system damage from neglected storage. The manuals split storage into time bands, and they don't use the same bands:
- Honda EU2200i: less than 1 month, nothing needed; 1 to 2 months, fill with fresh gasoline and add stabilizer; 2 months to 1 year, do that and also drain the carburetor float bowl; 1 year or more, drain the tank and carburetor, change the oil, and oil the cylinder.
- Westinghouse WGen12000DF: less than 1 month, nothing needed; 2 to 6 months, fresh gasoline plus stabilizer and drain the float bowl; 6 months or longer, drain the tank and float bowl.
- Champion 201159: up to 30 days, shut off the gasoline and let the engine run until it stops; 30 days to 1 year, add stabilizer, run 10 minutes, then drain the carburetor or run it dry; over 1 year, drain the tank and carburetor completely.
- Generac GP Series: either add stabilizer and run the engine 10 to 15 minutes (it says properly treated fuel can be stored up to 24 months), or drain untreated fuel into an approved container and run the engine until it stops.
- If you're stabilizing the fuel, treat a full tank and run it outdoors. Add a stabilizer made for gasoline storage to fresh fuel, following the stabilizer maker's directions (Honda). Honda says the air in a partly filled tank speeds fuel breakdown, and that warm storage does too. Generac says to run the engine 10 to 15 minutes, and Champion says 10 minutes, so treated fuel reaches the whole fuel system. Unplug everything from the generator first (Champion). Run it outdoors only, following the CO distances in the Safety box.
- Drain the carburetor or run it dry, if your manual says to. Honda (2 months to 1 year), Westinghouse (2 to 6 months), and Champion (30 days to 1 year) all have you empty the carburetor even when the tank holds stabilized fuel. Champion gives two options: shut the engine off, let it cool completely, and drain the carburetor through its drain bolt into a container using a funnel; or, with the engine running, turn the fuel dial to "gasoline off" and let it run until it stalls. Honda's EU2200i drains through a carburetor drain screw. Where the drain is and how to reach it varies by model, so follow your manual's diagram, and do it outdoors with the engine cool.
- For long storage, drain the tank too. Honda (1 year or more), Westinghouse (over 6 months), and Champion (over 1 year) say to empty the fuel tank and carburetor. Westinghouse says even properly stabilized fuel can leave residue and cause corrosion if left long term. Pump the fuel into an approved gasoline container with a hand pump, not an electric pump (Honda, Westinghouse), then run the engine until it stops, or drain the carburetor, as your manual describes (Westinghouse, Generac). Note that Generac's online FAQ is stricter than its GP Series manual: the FAQ highly recommends draining the tank and running the carburetor dry for storage longer than 30 days. Go with your own model's manual.
- Change the oil while the engine is warm, when your manual calls for it. Generac says to change the oil before storage, and Honda's storage table includes an oil change for storage of 1 year or more. Otherwise, follow your maintenance schedule (see the table below). Honda, Champion, and Generac all say to drain the oil while the engine is warm so it drains completely. Turn the engine off, disconnect the spark plug wire (Generac), drain the oil into a container, refill on a level surface with the oil type and amount in your manual, and don't overfill (Honda, Champion, Generac).
- Protect the cylinder, if your manual says to. Remove the spark plug, add a little clean engine oil, and crank the engine slowly to spread it. The amounts differ: Honda's EU2200i manual says about one teaspoon (5 cc) for storage of a year or more; Generac's GP Series manual says 5 to 10 cc (it calls this a tablespoon) of clean oil or a spray of fogging agent; Champion's 201159 manual says about a tablespoon. Wear eye protection while cranking (Generac). Reinstall the plug. Honda and Generac then say to pull the starter slowly until you feel resistance, which closes the valves so moisture can't get into the cylinder. The Westinghouse storage steps we read don't include this step, so skip it if your manual doesn't mention it.
- Clean it without hosing it down. Champion says not to spray the generator with water, because water can get through the cooling slots, damage the windings, and contaminate the fuel system; Generac also warns that water left in the windings reduces their insulation. Wipe it with a damp cloth (Honda, Champion, Westinghouse), brush off dirt (Champion), and make sure the air vents and cooling slots are clear (Champion, Westinghouse). Honda says that once it's dry, you can touch up damaged paint and coat parts that may rust with a light film of oil.
- Look after the battery (electric-start models). Charging systems differ, so check your manual:
- Champion 201159: the generator charges its battery while running, which keeps it charged if you use the generator about once every two weeks. If you use it less, keep it on a trickle charger or battery maintainer charging at no more than 1.5 amps, and make sure the battery is fully charged at least once a month.
- Westinghouse WGen12000DF: the generator charges the battery after 30 to 60 minutes of running, and the included trickle charger can stay connected indefinitely while it's not running. Charge in a dry place. For long-term storage, its fuel-draining steps end with turning the battery switch off and disconnecting the battery.
- Generac GP Series: the battery can lose charge when unused for long periods, and the manual says running the generator does not charge the battery; use the 12V charger that came with it.
- Store it in the right place. Store it level, because tilting or laying it on its side can leak fuel or oil (Honda). If any gasoline is left in it, Honda says to choose a well-ventilated area away from appliances with a flame, such as a furnace, water heater, or clothes dryer, and away from spark-producing motors and power tools. Champion and Westinghouse also say never to store the generator, gasoline, or propane cylinders near furnaces, water heaters, or other appliances that produce heat or have automatic ignition. Pick a dry spot: Honda says to avoid high humidity, and Champion says a cool, dry place out of direct sunlight. Westinghouse says to keep at least five feet of clearance on all sides, including overhead, while operating and storing. Set the controls for storage as your manual says. Champion says to set the fuel dial to "engine stop," and Honda says to leave the engine switch and fuel cap vent lever off unless the fuel is fully drained. Cover it only once it's cool. Honda and Westinghouse say not to use a plastic sheet because it traps moisture, while Generac calls for a protective, moisture-resistant cover, so use the kind of cover your manual describes.
- Keep stored gasoline fresh, or don't keep it. Generac says not to store fuel from one season to the next unless it's properly treated, recommends stabilizer in your storage can too, and says to replace a fuel container if it starts to rust.
Maintenance intervals in the manuals we checked
Winter is a common time to catch up on scheduled maintenance. These are the intervals printed in each manual. Follow whichever interval comes first, and service more often under heavy loads, in heat, or in dust, as the manuals say.
- Oil: Honda EU2200i: first month or 20 hours, then every 6 months or 100 hours. Westinghouse WGen12000DF: first 20 hours or first month, then every 100 hours or 6 months. Champion 201159: after the first 5 hours (break-in), then every 100 hours or annually. Generac GP Series: after the first 30 hours, then every season, and every 100 hours or every year. Generac's FAQ says after the first 20 to 30 hours and every 100 hours after that.
- Spark plug: Honda: check and adjust every 6 months or 100 hours, replace every year or 200 hours. Generac: replace every year. Champion: clean and adjust every 100 hours or annually. Westinghouse: inspect and clean every 100 hours or 6 months, replace every 300 hours or every year.
- Air filter and spark arrester: each manual lists its own cleaning interval. Some items, such as valve clearance, are marked for a dealer or an experienced owner (Honda, Champion).
Dual-fuel and propane generators
- Disconnect the propane. For storage and transport, close the cylinder valve, and disconnect the cylinder (Champion, Westinghouse). Westinghouse says to cover both the generator's propane inlet and the tank outlet with their protective plastic caps. Champion says to turn off the generator's LPG valve too, and to plug the cylinder outlet with its protective cap if one is available.
- Store the cylinder safely. Keep it upright and away from heat (Champion, Westinghouse), and not near furnaces, water heaters, or other appliances that produce heat or have automatic ignition (Champion, Westinghouse). Champion says cylinders shouldn't be exposed to sun, rain, or dust.
- Still deal with the gasoline side. The storage steps in Champion's and Westinghouse's dual-fuel manuals are written around the gasoline in the tank and carburetor, so follow the fuel steps above for the gas side too.
- Replace the hose on schedule. Champion's maintenance schedule says to check the LPG hose for leaks before each use and to replace it every 3 years.
Getting rid of old fuel, oil, and batteries
Dispose of drained gasoline according to local rules (Champion). The U.S. EPA treats leftover products that can catch fire, including oils, as household hazardous waste, and says not to pour them down drains, on the ground, or into storm sewers. It suggests asking your local environmental, health, or solid waste agency about collection. For used oil, put it in a sealed, leak-proof container and take it to a recycling center (Honda), or check with local auto shops, waste collectors, and government waste officials about drop-off (EPA). Honda says never to throw it in the trash, dump it on the ground, or pour it down a drain. Return a worn-out lead-acid starting battery to a battery retailer or a household hazardous waste program; the EPA says not to put lead-acid batteries in the trash or curbside recycling.
In spring (or before the first outage)
- Inspect it. Go through the before-use checks in your manual (Honda). Champion says to check the oil level and add oil if needed, and to clear bugs, cobwebs, or other blockages from the air filter area.
- Add fresh fuel. If you drained the tank, refill it with fresh gasoline, and make sure any gas can you use also holds only fresh fuel (Honda). Champion says to then turn the fuel dial on, wait 5 minutes, and check around the carburetor and air filter for gasoline leaks. If you find a leak, the carburetor needs to be cleaned or replaced.
- Reconnect the battery and propane. Reconnect the battery the way your manual shows (Generac and Westinghouse connect the positive cable first when installing). On dual-fuel models, check the LPG fittings and hose for leaks before use (Champion). Champion's manual describes using soapy water, where growing bubbles mean a leak, and says never to use a flame.
- Start it outdoors. If you oiled the cylinder, Honda says the engine may smoke briefly at startup and that this is normal. Plug in loads only after it's running and has warmed up (Generac).
- If it runs but makes no power. Generac's FAQ says generators in storage can lose their magnetism and stop producing electricity even when the engine runs. Check your manual or have an authorized service dealer look at it.
When to call a pro
Call a licensed electrician for any connection to your home's wiring, including installing a transfer switch (Honda, Champion, Generac, Westinghouse). Call a qualified technician if you find a propane leak (Champion). Take the generator to an authorized service dealer if fuel leaks from the carburetor, or if it was stored more than 30 days with untreated ethanol-blended gas: Champion says it then needs a full drain and carburetor cleaning, which it calls a technically advanced job. Also call a dealer if it won't start or runs poorly on fresh fuel (Generac lists a blocked or damaged carburetor and fuel line damage as possible causes), or for jobs your manual reserves for a dealer, such as valve clearance and fuel tank cleaning on the Honda.
Common mistakes and variations
Running it in the garage "just for a few minutes"
Running it during storage prep or a test run is exactly when people are tempted to stay out of the cold. CPSC says never to run it in a garage, even with the door open, and the CDC says to keep it more than 20 feet from windows, doors, and vents. Generac adds that a fan or an open door won't provide enough ventilation.
Leaving a half tank of untreated gas
Honda says air in a partly filled tank speeds fuel breakdown, and Generac says untreated fuel should be drained before storage. Either treat a full tank or drain it, as your manual says.
Exercise runs vs. a drained fuel system
Generac recommends starting and running the generator for 30 minutes every 30 days, and only preparing it for storage if you can't. Briggs & Stratton also suggests running it occasionally to keep the engine lubricated and keeping an electric-start battery charged. If you want it ready for winter outages, that usually means stabilized fuel and regular outdoor runs rather than a dry tank. If it will sit until spring, follow your manual's long-term storage steps instead.
Inverter vs. open-frame generators
The basic jobs are the same, but the details are model-specific. The inverter we checked, Honda's EU2200i, has a fuel cap vent lever that is turned off for storage, a carburetor drain screw behind a maintenance cover, and a maximum oil capacity of 14 oz (0.44 L). The open-frame Champion 201159 uses a single fuel dial with "gasoline off" and "engine stop" positions. Don't assume one brand's controls or procedure apply to another.
Covering it while it's hot
Generac warns that hot surfaces can start a fire under a cover. Wait until it has cooled (to room temperature, per Generac, or at least 30 minutes, per Westinghouse) before covering it.
FAQ
Should I drain the gas or use fuel stabilizer in my portable generator?
It depends on your manual and how long the generator will sit. Generac's GP Series manual allows either: add stabilizer and run the engine 10 to 15 minutes (it says treated fuel can be stored up to 24 months), or drain untreated fuel and run the engine until it stops. Generac's online FAQ is stricter and highly recommends draining the tank and running the carburetor dry for storage over 30 days. Honda's EU2200i manual says to add stabilizer to a full tank for 1 to 2 months, also drain the carburetor for 2 months to 1 year, and drain the tank and carburetor for 1 year or more. Westinghouse's WGen12000DF manual says to drain the tank for storage over 6 months, and Champion's 201159 manual says to drain everything for storage over 1 year. Follow your own owner's manual.
How far from the house should a generator be when I run it?
CPSC says at least 20 feet from the house, with the exhaust pointed away from the home, and never on a porch or in a carport. The CDC says more than 20 feet from any windows, doors, and vents, and Ready.gov says at least 20 feet from windows, doors, and attached garages. Never run it inside a home, garage, basement, crawlspace, or shed, even with doors or windows open (CPSC). Westinghouse notes that your home or wind conditions may require more distance.
Can I run my generator in the garage with the door open to test it?
No. CPSC says never to operate a portable generator in a garage or other enclosed space and that opening doors or windows won't provide enough ventilation to prevent lethal CO buildup. Generac's manual says a fan or an open door won't provide enough ventilation either. Carbon monoxide is colorless and odorless and can kill in minutes (CPSC). Run it outdoors only, following the distances above, and have battery-operated or battery-backup CO alarms in your home.
How often should I run my generator during the winter?
Generac's GP Series manual recommends starting it and running it for 30 minutes every 30 days, and preparing it for storage only if you can't. Champion says its generator keeps its battery charged if it's used about once every two weeks. Briggs & Stratton suggests running a generator occasionally to keep the engine lubricated. Always run it outdoors, away from the house. If you've drained the fuel system for long-term storage, follow your manual instead.
Do I need to keep the generator battery on a charger over winter?
Check your manual, because charging systems differ. Champion's 201159 manual says to use a trickle charger or battery maintainer charging at no more than 1.5 amps if the generator is used less than about every two weeks, and to fully charge the battery at least once a month. Westinghouse says its included trickle charger can stay connected indefinitely while the generator isn't running. Generac's GP Series manual says running the generator does not charge the battery, so use the included 12V charger. Batteries give off explosive gases while charging, so keep sparks and flames away (Generac).
Should I fog the engine or put oil in the cylinder?
Only if your manual says to. Honda's EU2200i manual says to put about a teaspoon (5 cc) of clean engine oil in the cylinder for storage of a year or more. Generac's GP Series manual says 5 to 10 cc of clean oil (it calls this a tablespoon) or a spray of fogging agent, and Champion's 201159 manual says about a tablespoon. Then crank the engine slowly to spread it and reinstall the spark plug. Wear eye protection while cranking (Generac).
Can I plug my generator into a wall outlet to power the house?
No. Champion's manual says connecting a generator to your home's wiring this way, called backfeeding, is dangerous and illegal in many states and municipalities. Honda says backfeed can electrocute utility workers or others who touch the lines and can make the generator explode, burn, or start fires when utility power returns. A connection to a building's wiring needs a transfer switch installed by a qualified or licensed electrician that keeps generator power separate from utility power and meets your electrical codes.
Sources
We checked these manuals and pages while writing this guide. Where they disagree, we say so above. Follow your own generator's owner's manual if it differs.
- EU2200i / EU2200i Companion Generator Owner's Manual (00X31-Z44-6170, © 2024) — HondaCarbon monoxide, electric shock, fire, and refueling warnings; connections to a building's electrical system and backfeed; CO-MINDER; maintenance schedule; engine oil change; storage table (under 1 month, 1–2 months, 2 months–1 year, 1 year or more); draining the fuel tank and carburetor; about one teaspoon (5 cc) of oil in the cylinder; storage precautions; removal from storage.
- GP Series Portable Generator Owner's Manual (Part No. A0005111410 Rev. B, 10/10/2024) — GeneracExhaust and CO hazards (a fan or open door won't provide enough ventilation); transfer switch installed by a qualified electrician; COsense; battery charging and warnings (running the generator does not charge the battery); maintenance schedule; oil change; storage (run 30 minutes every 30 days, stabilizer and 10–15 minute run, or drain; 5–10 cc of oil or fogging agent; cool before covering).
- Portable Generator FAQ & Troubleshooting — GeneracRecommends draining the tank and running the carburetor dry for storage over 30 days; oil change after the first 20–30 hours and every 100 hours; stored generators can lose magnetism; won't-start causes; let the generator warm up before connecting appliances.
- 201159 9500W Dual Fuel Electric Start Generator Operator's Manual — Champion Power EquipmentCO Shield; transfer switch installed by a licensed electrician; backfeeding warning; gasoline and propane safety; storing cylinders; cleaning (don't spray with water); oil change; maintenance schedule; battery (trickle charger at 1.5 A or less, full charge monthly); short-, mid-, and long-term storage; removing from storage, including propane leak checks.
- WGen12000DF Dual Fuel Portable Generator User Manual (121194 Rev07, 7/24/23) — Westinghouse Outdoor Power EquipmentCO and distance guidance; transfer switch installed by a qualified electrician; five feet of clearance and a 30-minute cool-down before storage; propane tank handling; battery maintenance and trickle charger; storage table (2–6 months, 6 months or longer); short- and long-term storage; maintenance schedule.
- Portable Generator Usage Tips — Briggs & Stratton (updated January 13, 2026)Keep an electric-start battery charged; run the generator occasionally to keep the engine lubricated; use fuel stabilizer for extended storage; let it cool before storing; use a storage cover.
- CPSC Issues Winter Weather Safety Tips to Prevent Fires and Carbon Monoxide Poisoning (March 16, 2026) — U.S. Consumer Product Safety CommissionNever operate a portable generator in a home, garage, basement, crawlspace, shed, or other enclosed space; open doors and windows don't provide enough ventilation; at least 20 feet from the house, not on a porch or in a carport; direct exhaust away; CO alarms; CO shut-off feature.
- Generators and Engine-Driven Tools — U.S. Consumer Product Safety CommissionCO from a generator can kill within minutes; never use portable generators indoors or in garages, basements, or sheds; use them outside, well away from windows, doors, and vents; keep a working CO alarm.
- What to Know About Generators and Carbon Monoxide (CO) (Pub. 468, 2022) — U.S. Consumer Product Safety CommissionCO is the invisible killer; never use a generator inside a home or garage even if doors and windows are open; at least 20 feet from the house; CO alarms; symptoms of CO poisoning.
- Carbon Monoxide (CO) Poisoning Basics — Centers for Disease Control and PreventionCO is an odorless, colorless gas; portable generators produce it; use generators outside, more than 20 feet from any windows, doors, and vents; never in a home or garage even with doors and windows open; battery or battery-backup CO detectors.
- Power Outages — Ready.gov (FEMA)Use generators outdoors and at least 20 feet from windows, doors, and attached garages; install CO detectors; keep the generator dry; let it cool before refueling because fuel spilled on hot engine parts can ignite.
- Managing, Reusing, and Recycling Used Oil — U.S. EPADo-it-yourselfers: collect used oil in a leak-proof container and check with local maintenance shops, waste collectors, and government waste officials about drop-off.
- Household Hazardous Waste (HHW) — U.S. EPALeftover products that can catch fire, including oils, are household hazardous waste; don't pour them down drains, on the ground, or into storm sewers; ask your local environmental, health, or solid waste agency about collection.
- Used Household Batteries — U.S. EPALead-acid batteries contain lead and sulfuric acid; return them to a battery retailer or a local household hazardous waste program and don't put them in the trash or municipal recycling.